Busbox-P2 Profibus Amplifier
|
 | |
The amplifier Busbox-P is used whenever strain gauge sensors are to be connected to the Profibus. The primary use is for web tension measurement. Generally the sensors are connected to the amplifier and the resulting average signal value is transmitted. This amplifier consists of an analog and a digital PCB. The system can power two sensors and process the measuring signals. The measurement values are converted into digital signals in the data formats specified for the Profibus. |
|
| Features |
- Amplifier with Profibus Interface
- Designed for one or two strain gauge sensors
- Transmission rate up to 12 Mbit/s
- User friendly commissioning via GSD file
|
| Data width: |
1 word |
| Resolution: |
16 bit |
| Design: |
Aluminium Field Enclosure, IP 67 |
| Strain gauge excitation supply: |
4.5 V, 18 mA
(Sensor A + B) |
|
|
|
|
|
|
|
|
|
|